PV1-F
REPS
Product Description
Single core flexible cables suited for photovoltaic and solar system with cross-linked polymer insulation and halogen free sheath. Tested for more 25 years lifetime. These cables can be used up 1800V to earth. Cable suitable for the interconnection of the various elements of photovoltaic systems, suitable for fixed installations outside and indoor, unprotected pipes. For direct, or indirect underground wiring.
Technical Data
Technical data Temperature range:
• Fixed installed: -40°C up to +90 °C
• Min. cable temperature at bending/installation: -40 °C
• Maximal operating temperature: 120 °C
• At short circuit of max. 5 s: up to 250 °C
Nominal voltage AC: U0 /U = 0,7/1,2kV
Nominal voltage DC: U0 /U = 0,9/1,8kV
Test voltage AC: 6kV Test voltage DC: 10kV
Maximal tensile strength of Cu conductor:
• During operation: 15 N/mm2
• During installation: 50 N/m2
Minimal inner bending radius: 4D (D = external cable diameter)
Properties under fire:
Flame retardant: acc. to IEC 60332-1 / EN 60332-1 (earlier EN 50265-2-1) / VDE 0482-332-1
No flame propagation in vertical cable bundle: acc. to IEC 60332-3 / EN 50266-1,-2 / DIN VDE 0482-266-2-4 (same as DIN VDE 0472 part 804 test method C)
Halogen-free: acc. to IEC 60754-1 / EN 50267 -1,-2-1 / DIN VDE 0482-267 -1,-2-1 (same as DIN VDE 0472 part 815) Non-corrosive combustion gases: acc. to IEC 60754-2 / EN 50267-2-2 / DIN VDE 0482-267-2-2 (same as DIN VDE 0472 part 813)
Low smoke density: acc. to IEC 61034-2 / EN 61034-2 (earlier EN 50268) / DIN VDE 0482-1034-2 (same as DIN VDE 0472 part 816) - visibility > 70%
Construction
1. Conductor: tinned fine wired copper conductor, class 5, acc. to EN 60228
2. Insulation: HEPR 120°C similar to IEC 60502-1 (type EI6/ EI8)
3. Sheath: crossed linked compound M21
• Sheath colour: black
Core colour identification: natural colour – bright
Additional features:
Ozone-resistant according to EN50396
UV-resistant according to HD605/A1
The cable is tested for durability according to EN 60216 (indicated also in 2P fg 169/08.2007)
Standard interpretation under continuous use temperature 120°C for 20000h (= 2.3, years) continuous use temperature 90°C (= 30 years )
Dimensions
Dimensions -number of cores x conductor crosS-section | Construction of individual conductor(No.of wiresx diameter) | External diameter | Conductor diameter | Insulation thickness | Cu weight | Cable weight |
Nominal N x mm² | Nominal n x mm | Approx. mm | Nominal mm | Nominal mm | kg/km | Approx. kg/km |
1x 1.5 | 30x0.25 | 5.1 | 1.6 | 0.7 | 38.4 | |
1x 2.5 | 50x0.25 | 5.4 | 2 | 0.7 | 24 | 45.4 |
1x 4 | 56×0.30 | 6.2 | 2.5 | 0.7 | 38.4 | 60.1 |
1x 6 | 84x0.30 | 6.9 | 3.1 | 0.7 | 57.6 | 90.7 |
1x 10 | 80x0.40 | 8.2 | 4.1 | 0.7 | 96 | 131.1 |
1x 16 | 128x0.40 | 9.3 | 5.2 | 153.6 | 187.1 | |
1x 25 | 200×0.40 | 10.8 | 6.5 | 0.9 | 240 | 276.1 |
1x 35 | 280x0.40 | 12.1 | 0.9 | 336 | 368.8 | |
1x 50 | 400×0.40 | 14.8 | 9 | 1 | 480 | 557 |
1x 70 | 356x0.50 | 16.9 | 11 | 1.1 | 672 | 767 |
1x 95 | 485x0.50 | 18.7 | 12.7 | 1.1 | 912 | 989.6 |
1x120 | 614x0.50 | 20.7 | 13.7 | 1152 | 1232.8 |